DR-100
Winston/OEM
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
2 years warranty
MODEL | DR-100-12 | DR-100-15 | DR-100-24 | |
OUTPUT
| DC VOLTAGE | 12V | 15V | 24V |
RATED CURRENT | 8.3A | 6.5A | 4.2A | |
CURRENT RANGE | 0 - 8.3A | 0 - 6.5A | 0-4.2A | |
RATED POWER | 100W | 100W | 100.8W | |
RIPPLE & NOISE (max.) | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 12- 15V | 15-18V | 24 - 29V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load | |||
HOLD UP TIME (Typ.) | 50ms/230VAC 18ms/115VAC at full load | |||
INPUT
| VOLTAGE RANGE | 88 ~ 264VAC 124 - 370VDC [DC input operation possible by connecting AC/L(+),AC/N(-)] | ||
FREQUENCY RANGE | 47 - 63Hz | |||
EFFICIENCY (Typ.) | 87% | 87% | 89% | |
AC CURRENT (Typ.) | 3A/115VAC 1.6A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 45A/230VAC | |||
PROTECTION
| OVERLOAD Note.6 | 105 -135% rated output power | ||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVERVOLTAGE | 16 ~ 20V | 19 -23V | 30 -35V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||
ENVIRONMENT
| WORKING TEMP. | -20 - +60"C (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 - +85 °C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/oC(0~50°C) | |||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
OTHERS
| MTBF | 486K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 100*93*56mm (W*H*D) | |||
PACKING | 0.35Kg; 35pcs/16.5Kg/0.89CUFT |
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
2 years warranty
MODEL | DR-100-12 | DR-100-15 | DR-100-24 | |
OUTPUT
| DC VOLTAGE | 12V | 15V | 24V |
RATED CURRENT | 8.3A | 6.5A | 4.2A | |
CURRENT RANGE | 0 - 8.3A | 0 - 6.5A | 0-4.2A | |
RATED POWER | 100W | 100W | 100.8W | |
RIPPLE & NOISE (max.) | 120mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 12- 15V | 15-18V | 24 - 29V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 2700ms, 80ms/230VAC 2700ms, 80ms/115VAC at full load | |||
HOLD UP TIME (Typ.) | 50ms/230VAC 18ms/115VAC at full load | |||
INPUT
| VOLTAGE RANGE | 88 ~ 264VAC 124 - 370VDC [DC input operation possible by connecting AC/L(+),AC/N(-)] | ||
FREQUENCY RANGE | 47 - 63Hz | |||
EFFICIENCY (Typ.) | 87% | 87% | 89% | |
AC CURRENT (Typ.) | 3A/115VAC 1.6A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 45A/230VAC | |||
PROTECTION
| OVERLOAD Note.6 | 105 -135% rated output power | ||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||
OVERVOLTAGE | 16 ~ 20V | 19 -23V | 30 -35V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||
ENVIRONMENT
| WORKING TEMP. | -20 - +60"C (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 - +85 °C, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/oC(0~50°C) | |||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1 cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
OTHERS
| MTBF | 486K hrs min. MIL-HDBK-217F (25°C) | ||
DIMENSION | 100*93*56mm (W*H*D) | |||
PACKING | 0.35Kg; 35pcs/16.5Kg/0.89CUFT |