UDC-18GM-400-3E1 Ultrasonic Double Sheet Sensor Sensing range 20 ... 60 mm , optimal distance: 45 mm, Ultrasonic system for reliable detection of no, one, or two overlapping sheet materials, preferably papers. The housing material is nickel plated brass; plastic components: PBT, 150g.
Availability:
Quantity:
  • UDC-18GM-400-3E1

  • Winston

 Feature 

  • Ultrasonic system for reliable detection of no, one, or two overlapping sheet materials, preferably papers

  •  No TEACH-IN required

  •  Function indicators visible from all directions

  •  Insensitive to printing, colors, and shining surfaces

  •  Material weight from 10 g/m 2 up to over 2000 g/m 2

  •  Very wide material spectrum, finest papers up to thin sheet metals as well as plastic- and metal foils

  •  Perpendicular or inclined sensor mounting relative to the sheet plane possible

  •  Programmable

Description of sensor functions

The ultrasonic double sheet monitor is used for double sheet detection in all situations in which the automatic distinction between double and single sheets is required in order to protect machines or avoid waste production. The double-sheet monitor is based on the ultrasonic through-beam principle. The following can be detected:
- No sheet, i.e. air,
- Individual sheet
- Double sheet
A microprocessor system evaluates the signals. The appropriate switch outputs are set as a result of the evaluation. Changes in ambient conditions such as temperature and humidity are compensated for automatically. The interface electronics is integrated into a compact M18 metal housing together with a sensor head.

 

Switching on
The sensor is equipped with 6 connections. The functionality of the connections is described in the following table. The function input
(PK) is used to assign parameters to the sensor. (See Output pulse extension, Alignment aid and Program selection). During normal
operation, the function input must always be securely connected with +U B or -U B , to avoid possible interference or improper functionality.

Colour Switching on Comments
BN +U B
WH Switch output for single sheets Pulse width corresponds to the event
BK Switch output for double sheets Pulse width corresponds to the event
GY Switch output for air Pulse width corresponds to the event
PK -U B /+U B Function input for parameter assignment/
pulse prolongation
BU -UB

 

Normal mode
The sensor is working in normal mode if the function input (PK) is applied to -U B or +U B when the power source (Power-On) is supplied,
as shown in the output pulse extension table (see below).
Displays:
LED yellow:      Detection of air
LED green:      Detection of single sheets
LED red:          Detection of double sheets
Switch outputs:
The switch outputs are only active in normal operation!
White:      WH     Single sheet output
Black:      BK      Double sheet output
Gray:       GY       Air output

 

Procedure for assigning parameters
It is possible to switch to additional parameter assignment modes from the display mode:
         Alignment mode -->
         Program selection mode -->
         Alignment aid mode --> (for checking)
When the function input (PK) is applied to -U B (for > 500 ms), the mode changes. When the "Program selection“ mode is active, swit-
ching on function input (PK) on to +U B (for > 500 ms) selects the next program level.
Disconnecting the power supply causes the system to exit the current mode with the selected program change.
The switch outputs are not active while parameters are being assigned to the sensor!

FUNCTION.jpg

Modes
Amplitude control
During installation, the amplitude control can be used to check whether the ultrasonic amplitude at the receiver is sufficient. If the transmitter is not aligned properly in relation to the receiver, maximum sound energy is not transmitted to the receiver, which may result in the incorrect detection of materials.
When the sensor detects an area of air (yellow LED lights up), the UDC begins to display the strength of the measured amplitude signal:
- if the signal is weak, the yellow LED flashes at low frequency
- the flashing frequency increases in line with the signal strength
- the yellow LED lights up continuously when the signal strength is sufficient.
The single sheet function (green LED) and double sheet function (red LED) are now active. This can be used to check the correct
function of the sensor.
Program selection
In the program selection mode, the current program is displayed by the green LED (number of flashing pulses = program number).
Applying the adjustment input (PK) to +U B (for > 500 ms) causes the next program to be selected in cyclic sequence (program 1 follows through to program 4).

data.jpg

Diagrams           

mounting.jpg


Dimension          

dimension.jpg

Additional information          

additional information.jpgadditional information 2.jpg

Connection         

electrical connection.jpg

Previous: 
Next: 
Professional manufacturer, quality is our culture!
READ MORE>>

Subscribe

Products

Quick Links

Contact Us

Tel: 0086-577-27852809
Fax: 0086-577-61738060
Mob: 0086-13757875820
Whatsapp:0086-13757875820
E-mail: wstele@wstele.net
Skype:wstele
QQ: 2853768221
​Copyright © 2016 YUEQING WINSTON ELECTRIC CO.,LTD  All Rights Reserved. Site Map