10KV series
The full-sealing power transformer cancels the oil conservator; and the fin plate of corrugated oil tank body is taken as the cooling component, and meanwhile, is expanded and shrunk with the increase and decrease of transformer ol, so that the transformer interior is isolated with the atmosphere, thereby preventing thel degradation, insulation moisture and aging of oll, and enhancing the operational reliability. The iron core is made of high-quality cold rolled silicon steel sheet, thereby effectively improving the distribution situation of magnetic flux density in the iron core, reducing the noise, and reducing the loss. The coil is wound with high strength enamelled wire (or paper covered wire), and is in a cylindrical (or cake) structure, the ampere turn is distributed uniforrmty, and the insulation structure is reasonable and has strong anti-short circuit ability. The fasteners used in the oil tank are stop nuts, which can guarantee the loosening when operating after the long-distance transport. The oil tank surface is used for three-proofing lacquer (dampproof, mouldproof and salt-spray proof) coating after being phosphate, and thus, is widely used in the metalurgy, mine, petrifaction and other occasions with the bad environment.
Ordering instruction
Please provide the following parameters when ordering:1. Product model 2. Rated capacity 3. Voltage combination4. Adjustment range 5. Frequency 6. Connection symbol7. Short-circuit impedance8. Please note the technical requirements for the products having the special requirements
The full-sealing power transformer cancels the oil conservator; and the fin plate of corrugated oil tank body is taken as the cooling component, and meanwhile, is expanded and shrunk with the increase and decrease of transformer ol, so that the transformer interior is isolated with the atmosphere, thereby preventing thel degradation, insulation moisture and aging of oll, and enhancing the operational reliability. The iron core is made of high-quality cold rolled silicon steel sheet, thereby effectively improving the distribution situation of magnetic flux density in the iron core, reducing the noise, and reducing the loss. The coil is wound with high strength enamelled wire (or paper covered wire), and is in a cylindrical (or cake) structure, the ampere turn is distributed uniforrmty, and the insulation structure is reasonable and has strong anti-short circuit ability. The fasteners used in the oil tank are stop nuts, which can guarantee the loosening when operating after the long-distance transport. The oil tank surface is used for three-proofing lacquer (dampproof, mouldproof and salt-spray proof) coating after being phosphate, and thus, is widely used in the metalurgy, mine, petrifaction and other occasions with the bad environment.
Ordering instruction
Please provide the following parameters when ordering:1. Product model 2. Rated capacity 3. Voltage combination4. Adjustment range 5. Frequency 6. Connection symbol7. Short-circuit impedance8. Please note the technical requirements for the products having the special requirements
Rated capacity | Voltage combination and tapping range | Join group label | No-load current (%) | No-load loss (W) | Load loss (W) | Impedance voltage | ||||||
High voltage (KV) | High pressure tap range % | Low voltage (KV) | NX1 | NX2 | NX3 | NX1 | NX2 | NX3 | ||||
30 | 6 6.3 10 10.5 | ±2*2.5 ±5 | 0.4 | Dyn11 Yy0 | 1.50 | 61 | 70 | 80 | 455 | 505 | 630 | 4.0 |
50 | 1.30 | 80 | 90 | 100 | 655 | 730 | 910 | |||||
63 | 1.20 | 90 | 100 | 110 | 785 | 870 | 1090 | |||||
80 | 1.20 | 105 | 115 | 130 | 945 | 1050 | 1310 | |||||
100 | 1.10 | 120 | 135 | 150 | 1140 | 1265 | 1580 | |||||
125 | 1.10 | 135 | 150 | 170 | 1360 | 1510 | 1890 | |||||
160 | 1.00 | 160 | 180 | 200 | 1665 | 1850 | 2310 | |||||
200 | 0.90 | 190 | 215 | 240 | 1970 | 2185 | 2730 | |||||
250 | 0.80 | 230 | 260 | 290 | 2300 | 2560 | 3200 | |||||
315 | 0.80 | 270 | 305 | 340 | 2760 | 3065 | 3830 | |||||
400 | 0.80 | 330 | 370 | 410 | 3250 | 3615 | 4520 | |||||
500 | 0.80 | 385 | 430 | 480 | 3900 | 4330 | 5410 | |||||
630 | 0.60 | 460 | 510 | 570 | 4460 | 4960 | 6200 | 4.5 | ||||
800 | 0.60 | 560 | 630 | 700 | 5400 | 6000 | 7500 | |||||
1000 | 0.60 | 665 | 745 | 830 | 7415 | 8240 | 10300 | |||||
1250 | 0.50 | 780 | 870 | 970 | 8640 | 9600 | 12000 | |||||
1600 | 0.50 | 940 | 1050 | 1170 | 10440 | 11600 | 14500 | |||||
2000 | 0.40 | 1085 | 1225 | 1360 | 13180 | 14640 | 18300 | 5.0 | ||||
2500 | 0.40 | 1280 | 1440 | 1600 | 13360 | 14840 | 21200 |
Rated capacity | Voltage combination and tapping range | Join group label | No-load current (%) | No-load loss (W) | Load loss (W) | Impedance voltage | ||||||
High voltage (KV) | High pressure tap range % | Low voltage (KV) | NX1 | NX2 | NX3 | NX1 | NX2 | NX3 | ||||
30 | 6 6.3 10 10.5 | ±2*2.5 ±5 | 0.4 | Dyn11 Yy0 | 1.50 | 61 | 70 | 80 | 455 | 505 | 630 | 4.0 |
50 | 1.30 | 80 | 90 | 100 | 655 | 730 | 910 | |||||
63 | 1.20 | 90 | 100 | 110 | 785 | 870 | 1090 | |||||
80 | 1.20 | 105 | 115 | 130 | 945 | 1050 | 1310 | |||||
100 | 1.10 | 120 | 135 | 150 | 1140 | 1265 | 1580 | |||||
125 | 1.10 | 135 | 150 | 170 | 1360 | 1510 | 1890 | |||||
160 | 1.00 | 160 | 180 | 200 | 1665 | 1850 | 2310 | |||||
200 | 0.90 | 190 | 215 | 240 | 1970 | 2185 | 2730 | |||||
250 | 0.80 | 230 | 260 | 290 | 2300 | 2560 | 3200 | |||||
315 | 0.80 | 270 | 305 | 340 | 2760 | 3065 | 3830 | |||||
400 | 0.80 | 330 | 370 | 410 | 3250 | 3615 | 4520 | |||||
500 | 0.80 | 385 | 430 | 480 | 3900 | 4330 | 5410 | |||||
630 | 0.60 | 460 | 510 | 570 | 4460 | 4960 | 6200 | 4.5 | ||||
800 | 0.60 | 560 | 630 | 700 | 5400 | 6000 | 7500 | |||||
1000 | 0.60 | 665 | 745 | 830 | 7415 | 8240 | 10300 | |||||
1250 | 0.50 | 780 | 870 | 970 | 8640 | 9600 | 12000 | |||||
1600 | 0.50 | 940 | 1050 | 1170 | 10440 | 11600 | 14500 | |||||
2000 | 0.40 | 1085 | 1225 | 1360 | 13180 | 14640 | 18300 | 5.0 | ||||
2500 | 0.40 | 1280 | 1440 | 1600 | 13360 | 14840 | 21200 |