Availability: | |
---|---|
Quantity: | |
CJX2(LC1-D) AC Contactor (Magnetic Contactor/Reversing Contactors and Latching Contactors) composed of contacts, electromagnet and enclosure, are designed to be directly connected to high-current load devices. The AC contactors suitable for using in the circuits up to the rated voltage 600V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently starting & machine-interlocking device etc. It becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC947-2, VDE0660 & BS545.
CJX2(LC1-D) AC Contactor (Magnetic Contactor/Reversing Contactors and Latching Contactors) composed of contacts, electromagnet and enclosure, are designed to be directly connected to high-current load devices. The AC contactors suitable for using in the circuits up to the rated voltage 600V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently starting & machine-interlocking device etc. It becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC947-2, VDE0660 & BS545.
Specification:
Type | CJX2-D09 | CJX2-D12 | CJX2-D18 | CJX2-D25 | CJX2-D32 | CJX2-D40 | CJX2-D50 | CJX2-D65 | CJX2-D80 | CJX2-D95 | |
Rated workingcurrent (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
Standardpower ratingsof 3-phasemotors50/60Hz incategory AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 | |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 | |
Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 | |
Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
AC4 (x104) | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
Number of the contacts | 3P+NO | 3P+NC+NO | |||||||||
3P+NC |
Type | CJX2-D115 | CJX2-D150 | CJX2-D170 | CJX2-D205 | CJX2-D245 | CJX2-D300 | CJX2-D410 | CJX2-D475 | CJX2-D620 | |
Rated workingcurrent (A) | AC3 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
AC4 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 | |
Standard powerratings of 3-phase motors50/60Hz incategory AC-3 | 220/230V | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
380/400V | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 | |
415V | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 280 | 375 | |
500V | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 | |
660/690V | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 | |
Rated heat current (A) | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 | |
Electrical life | AC3 (x104) | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
AC4 (x104) | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 | |
Mechanical life (x104) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
Standard Control Circuit Voltage
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
Outline and Mounting Dimension
Type | A | B | C | D | E | a | b | Φ |
CJX2-D09~12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 4.5 |
CJX2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
CJX2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
CJX2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
CJX2-D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
CJX2-D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
Type | A | B | C | b1 | P | Q | S | Q1 | M | N | L | Φ | Ga | Ha |
CJX2-D115 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D150 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D170 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D205 | 168.5 | 174 | 181 | 137 | 40 | 69 | 20 | 59.4 | 154 | 127 | 113.5 | M8 | 80 | 120-106 |
CJX2-D245 | 168.5 | 197 | 181 | 137 | 48 | 69 | 25 | 51.5 | 172 | 127 | 113.5 | M10 | 80 | 120-106 |
CJX2-D300 | 213 | 206 | 219 | 145 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
CJX2-D410 | 213 | 206 | 219 | 209 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
CJX2-D475 | 233 | 238 | 232 | 209 | 55 | 108 | 30 | 77 | 208 | 172 | 146 | M10 | 80 | 180 |
CJX2-D620 | 309 | 304 | 255 | 280 | 80 | 140 | 40 | 89 | 264 | 202 | 155 | M12 | 80 | 180 |
Auxiliary contact block
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor I | LA1-DN10C | |
LA1-DN01C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor II | LA1-DN11C | |
LA1-DN20C | ||
LA1-DN02C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C | |
LA1-DN31C | ||
LA1-DN22C | ||
LA1-DN13C | ||
LA1-DN04C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C | |
LA1-DN31C | ||
LA1-DN22C | ||
LA1-DN13C | ||
LA1-DN04C |
Appellation | Type | |
Side-mounted auxiliary module | LA8-DN11C | |
LA8-DN20C |
LA2 time delay auxiliary contact block
Appellation | Type | |
Auxiliary instantaneouscontactor block,contactor IV | 0.1...3S LA2-DT0 | |
0.1...30S LA2-DT2 | ||
10...180S LA2-DT4 | ||
1...30S LA2-DS2 |
Appellation | Type | |
Time delay auxiliary contactorblock releasing and delay | 0.1...3S LA2-DT0 | |
0.1...30S LA3-DT2 | ||
10...180S LA3-DT4 |
Contactor | Auxiliary Blocks | Relative products | ||||
| | | | | ||
| | | | | ||
| | | | | ||
| | | | | ||
| | | | | | |
Specification:
Type | CJX2-D09 | CJX2-D12 | CJX2-D18 | CJX2-D25 | CJX2-D32 | CJX2-D40 | CJX2-D50 | CJX2-D65 | CJX2-D80 | CJX2-D95 | |
Rated workingcurrent (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
Standardpower ratingsof 3-phasemotors50/60Hz incategory AC-3 | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 | |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 | |
Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 | |
Electrical life | AC3 (x104) | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
AC4 (x104) | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
Mechanical life (x104) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
Number of the contacts | 3P+NO | 3P+NC+NO | |||||||||
3P+NC |
Type | CJX2-D115 | CJX2-D150 | CJX2-D170 | CJX2-D205 | CJX2-D245 | CJX2-D300 | CJX2-D410 | CJX2-D475 | CJX2-D620 | |
Rated workingcurrent (A) | AC3 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
AC4 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 | |
Standard powerratings of 3-phase motors50/60Hz incategory AC-3 | 220/230V | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
380/400V | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 | |
415V | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 280 | 375 | |
500V | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 | |
660/690V | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 | |
Rated heat current (A) | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 | |
Electrical life | AC3 (x104) | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
AC4 (x104) | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 | |
Mechanical life (x104) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
Standard Control Circuit Voltage
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 600 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | - | U6 | Q6 | - | - | R6 | - | - |
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | - | - |
Outline and Mounting Dimension
Type | A | B | C | D | E | a | b | Φ |
CJX2-D09~12 | 47 | 76 | 82 | 113 | 133 | 34/35 | 50/60 | 4.5 |
CJX2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
CJX2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
CJX2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
CJX2-D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
CJX2-D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
Type | A | B | C | b1 | P | Q | S | Q1 | M | N | L | Φ | Ga | Ha |
CJX2-D115 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D150 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D170 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | - | - |
CJX2-D205 | 168.5 | 174 | 181 | 137 | 40 | 69 | 20 | 59.4 | 154 | 127 | 113.5 | M8 | 80 | 120-106 |
CJX2-D245 | 168.5 | 197 | 181 | 137 | 48 | 69 | 25 | 51.5 | 172 | 127 | 113.5 | M10 | 80 | 120-106 |
CJX2-D300 | 213 | 206 | 219 | 145 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
CJX2-D410 | 213 | 206 | 219 | 209 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
CJX2-D475 | 233 | 238 | 232 | 209 | 55 | 108 | 30 | 77 | 208 | 172 | 146 | M10 | 80 | 180 |
CJX2-D620 | 309 | 304 | 255 | 280 | 80 | 140 | 40 | 89 | 264 | 202 | 155 | M12 | 80 | 180 |
Auxiliary contact block
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor I | LA1-DN10C | |
LA1-DN01C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor II | LA1-DN11C | |
LA1-DN20C | ||
LA1-DN02C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C | |
LA1-DN31C | ||
LA1-DN22C | ||
LA1-DN13C | ||
LA1-DN04C |
Appellation | Type | |
Auxiliary instantaneous contactor block,contactor IV | LA1-DN40C | |
LA1-DN31C | ||
LA1-DN22C | ||
LA1-DN13C | ||
LA1-DN04C |
Appellation | Type | |
Side-mounted auxiliary module | LA8-DN11C | |
LA8-DN20C |
LA2 time delay auxiliary contact block
Appellation | Type | |
Auxiliary instantaneouscontactor block,contactor IV | 0.1...3S LA2-DT0 | |
0.1...30S LA2-DT2 | ||
10...180S LA2-DT4 | ||
1...30S LA2-DS2 |
Appellation | Type | |
Time delay auxiliary contactorblock releasing and delay | 0.1...3S LA2-DT0 | |
0.1...30S LA3-DT2 | ||
10...180S LA3-DT4 |
Contactor | Auxiliary Blocks | Relative products | ||||
| | | | | ||
| | | | | ||
| | | | | ||
| | | | | ||
| | | | | | |
This is winston electric ac contactor. We opened this product for more details.
This is a base, the material is PA66 flame retardant.
And this one is iron core. It has 32pcs and the material is silicon steel core.
For this one is a coil. As you can see, we made it with full red copper.
This is winston electric ac contactor. We opened this product for more details.
This is a base, the material is PA66 flame retardant.
And this one is iron core. It has 32pcs and the material is silicon steel core.
For this one is a coil. As you can see, we made it with full red copper.