GMC Series
CE
Winston/OEM
Made in China
Export standard carton box
PCS
10
3-7days
1
T/T
1.Application:
GMC Series AC Contactor is suitable for using in the circuit up to the rated voltage 660V AC 50/60Hz,
Rated Current to 95A.For making breaking,frequently starting and controlling the AC motor.Combined
with the auxiliary contact block,timer delay&machine-interlocking device etc,it becomes the delay
contactor,mechanical interlocking contactor,star delta starter.With the thermal relay,it is combined into
the electromagnetic starter.
The products comply with IEC60947-4.
2.Specifications:
Type | GMC-9 | GMC-12 | GMC-18 | GMC-22 | GMC-32 | ||
IEC- 60947 | AC-1 duty | 25A | 25A | 40A | 40A | 50A | |
AC-3 duty | 200-240v | 2.5KW 11A | 3.5KW 13A | 4.5KW 18A | 5.5KW 22A | 7.5KW 32A | |
380-440v | 4KW 9A | 5.5KW 12A | 7.5KW 18A | 11KW 22A | 15KW 32A | ||
500-550v | 4KW 7A | 7.5KW 12A | 7.5KW 13A | 15KW 22A | 18.5KW 28A | ||
690v | 4KW 5A | 7.5KW 9A | 7.5KW 9A | 15KW 18A | 18.5KW 20A | ||
Life time (unit:10,000time) | Electrical | 250 | 250 | 250 | 250 | 200 | |
Mechanical | 2500 | 2500 | 2500 | 2500 | 1500 | ||
Auxiliary contact | Standard | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | C |
Type | GMC-40 | GMC-50 | GMC-65 | GMC-75 | GMC-85 | ||||
IEC- 60947 | AC-1 duty | 60A | 80A | 100A | 110A | 135A | |||
AC-3 duty | 200-240V | 11KW 40A | 15KW 55A | 18.5KW 65A | 22KW 75A | 25KW 85A | |||
380-440V | 18.5KW 40A | 22KW 50A | 30KW 65A | 37KW 75A | 45KW 85A | ||||
500-550V | 22KW 32A | 30KW 43A | 33KW 35A | 37KW 64A | 45KW 75A | ||||
690V | 22KW 23A | 30KW 28A | 33KW 35A | 37KW 42A | 45KW 45A | ||||
Life time (10,000 time) | Electrical | 200 | 200 | 200 | 200 | 200 | |||
Mechanical | 1500 | 1000 | 1000 | 1000 | 1000 | ||||
Auxiliary contact | Standard | 2NO+2NC | 2NO+2NC | 2NO+2NC | 2NO+2NC | 2NO+2NC |
GMC-9,12,18,22
GMC-32,40
GMC-50,65,75,85
1.Application:
GMC Series AC Contactor is suitable for using in the circuit up to the rated voltage 660V AC 50/60Hz,
Rated Current to 95A.For making breaking,frequently starting and controlling the AC motor.Combined
with the auxiliary contact block,timer delay&machine-interlocking device etc,it becomes the delay
contactor,mechanical interlocking contactor,star delta starter.With the thermal relay,it is combined into
the electromagnetic starter.
The products comply with IEC60947-4.
2.Specifications:
Type | GMC-9 | GMC-12 | GMC-18 | GMC-22 | GMC-32 | ||
IEC- 60947 | AC-1 duty | 25A | 25A | 40A | 40A | 50A | |
AC-3 duty | 200-240v | 2.5KW 11A | 3.5KW 13A | 4.5KW 18A | 5.5KW 22A | 7.5KW 32A | |
380-440v | 4KW 9A | 5.5KW 12A | 7.5KW 18A | 11KW 22A | 15KW 32A | ||
500-550v | 4KW 7A | 7.5KW 12A | 7.5KW 13A | 15KW 22A | 18.5KW 28A | ||
690v | 4KW 5A | 7.5KW 9A | 7.5KW 9A | 15KW 18A | 18.5KW 20A | ||
Life time (unit:10,000time) | Electrical | 250 | 250 | 250 | 250 | 200 | |
Mechanical | 2500 | 2500 | 2500 | 2500 | 1500 | ||
Auxiliary contact | Standard | 1NO+1NC | 1NO+1NC | 1NO+1NC | 1NO+1NC | C |
Type | GMC-40 | GMC-50 | GMC-65 | GMC-75 | GMC-85 | ||||
IEC- 60947 | AC-1 duty | 60A | 80A | 100A | 110A | 135A | |||
AC-3 duty | 200-240V | 11KW 40A | 15KW 55A | 18.5KW 65A | 22KW 75A | 25KW 85A | |||
380-440V | 18.5KW 40A | 22KW 50A | 30KW 65A | 37KW 75A | 45KW 85A | ||||
500-550V | 22KW 32A | 30KW 43A | 33KW 35A | 37KW 64A | 45KW 75A | ||||
690V | 22KW 23A | 30KW 28A | 33KW 35A | 37KW 42A | 45KW 45A | ||||
Life time (10,000 time) | Electrical | 200 | 200 | 200 | 200 | 200 | |||
Mechanical | 1500 | 1000 | 1000 | 1000 | 1000 | ||||
Auxiliary contact | Standard | 2NO+2NC | 2NO+2NC | 2NO+2NC | 2NO+2NC | 2NO+2NC |
GMC-9,12,18,22
GMC-32,40
GMC-50,65,75,85