Application
L7,L8 and L9 series circuit breaker are used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fireresistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/ 60Hz single pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Specifications
Model | PL7-63/2/C |
Standard | IEC/EN 60898-1 |
Number of poles | 1P,2P,3P,4P |
Rated Current (A) | 2,4,6,10,16,20,25,32,40,50,63 |
Rated Voltage (V) | 240/400VAC;50/60Hz |
Maximum operating voltage | 240/400 VAC |
Insulation Voltage | greater than or equal to 250V pase-ground and 400V phase-phase |
Working Temperature | -25°C a +55°C |
Withstandable impulse voltage | Greather than or equal 4kV |
Breaking Capacity | 10KA IEC-EN60898-230/400V |
Electrical Lifre | Not less than 10 000 times |
Mechanical Life | Not less than 20 000 times |
Characteristic Curve | C |
Enclosed Class | IP40 |
Class | IEC-EN60898 3 Class |
Over Voltage category | III |
Intallation | 35mm DIN Rail |
Housing Material | Not les than Nylon PA 66 |
Dimension
Packaging & Shipping
Application
L7,L8 and L9 series circuit breaker are used in lighting distribution system or motor distribution system for protection overload and short-circuit in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fireresistant and shockproof plastics. The product, with long life, is mainly used in AC 50Hz/ 60Hz single pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Specifications
Model | PL7-63/2/C |
Standard | IEC/EN 60898-1 |
Number of poles | 1P,2P,3P,4P |
Rated Current (A) | 2,4,6,10,16,20,25,32,40,50,63 |
Rated Voltage (V) | 240/400VAC;50/60Hz |
Maximum operating voltage | 240/400 VAC |
Insulation Voltage | greater than or equal to 250V pase-ground and 400V phase-phase |
Working Temperature | -25°C a +55°C |
Withstandable impulse voltage | Greather than or equal 4kV |
Breaking Capacity | 10KA IEC-EN60898-230/400V |
Electrical Lifre | Not less than 10 000 times |
Mechanical Life | Not less than 20 000 times |
Characteristic Curve | C |
Enclosed Class | IP40 |
Class | IEC-EN60898 3 Class |
Over Voltage category | III |
Intallation | 35mm DIN Rail |
Housing Material | Not les than Nylon PA 66 |
Dimension