High degree of protection Easy to install It has becomemore andmore important to provide a protected enclosure environment for valuable and crucial electrical and electronic components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation.When this occurs, the risk of dust and humidity being absorbed into the control panel increases dramatically. The specially designed pressure compensation device DA 084 permits a controlled change in pressure. It can be installed easily in any enclosure. The pressure compensation device is suitable for the use in enclosures and switch cabinets in accordance with DIN EN 62208.
Pressure Compensation Device DA 084
High degree of protection Easy to install It has becomemore andmore important to provide a protected enclosure environment for valuable and crucial electrical and electronic components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation.When this occurs, the risk of dust and humidity being absorbed into the control panel increases dramatically. The specially designed pressure compensation device DA 084 permits a controlled change in pressure. It can be installed easily in any enclosure. The pressure compensation device is suitable for the use in enclosures and switch cabinets in accordance with DIN EN 62208.
Technical Data
Mounting
PG 29 thread with union nut
Torque
5Nm (max. 10Nm)
Material
plastic according to UL94 V-0, pebble grey
Sealing
sealing gasket NBR
Air interface
approx. 7cm⊃2;
Dimensions
Ø 65.5mm x 30.5mm
Fitting position
vertical*
Operating/Storage temperature
-45 to +70°C (-49 to +158°F)
Protection type is restricted to IP54 if fitting position of DA 084 is not vertical. InstallationMake cut-out Ø 37+1mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.
Art. No.
Protection type
1 packing unit
Weight (approx.)
08400.0-04
IP55
2 pieces
62g (31g/pc.)
Technical drawing
Technical Data
Mounting
PG 29 thread with union nut
Torque
5Nm (max. 10Nm)
Material
plastic according to UL94 V-0, pebble grey
Sealing
sealing gasket NBR
Air interface
approx. 7cm⊃2;
Dimensions
Ø 65.5mm x 30.5mm
Fitting position
vertical*
Operating/Storage temperature
-45 to +70°C (-49 to +158°F)
Protection type is restricted to IP54 if fitting position of DA 084 is not vertical. InstallationMake cut-out Ø 37+1mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.